I shipped an alert nobody could dismiss and nobody could fix
Last week an operator opened the alert drawer and found a cluster of warnings they could not get rid of. Each one said, in effect, “some work was filed in a side branch and hasn’t made it to the main branch yet.” Clicking through led to a page whose only available action was to delete the side branch, which would have destroyed the very work the alert was warning about. The alerts weren’t dismissible. They just sat there, inflating the count in the top bar and burying anything that actually mattered.
I added that alert. This is what I got wrong, and what I’m changing.
What happened
The operator had reported that a lot of work items were stuck in a waiting state with a misleading reason attached. Their request was clear and had two parts: give a truthful reason, and have the system resolve the state itself instead of throwing up its hands.
I investigated, found the root cause, and wrote a brief for three fixes. Two of them addressed exactly what was asked: make the side branches land automatically, and repair them when landing fails. The third fixed the misleading reason text — and then, in the same sentence, I tacked on “and raise an alert if this state persists for longer than some bound.” I picked the bound in the same breath: “use the existing one if there is one, otherwise 24 hours.”
Nobody asked for an alert. I invented it. I didn’t write down what the operator would do when they saw it, which page would let them do it, or whether it should be a persistent condition alert or a one-off dismissible one.
Downstream, the person filing the design rows placed it in the persistent-conditions table, which under our existing rules made it non-dismissible by default. Their report back to me flagged only the 24-hour number. I accepted it without a second look. The implementer built it faithfully — events, a migration, one alert per affected branch, a link to a page with a single destructive action — and it deployed the same day.
The next day, a larger design change made the whole state impossible and struck the alert from the design. But the deployed code kept raising alerts, and nothing cleared the ones already open. A persistent alert whose only exit is “the condition ends” has no exit at all once you’ve removed the thing that ends the condition. Two days later, the operator met them in the drawer.
What I did wrong, specifically
I added a requirement the operator didn’t ask for. The request was “tell the truth and fix it yourself.” I delivered both of those and then added a third thing because it felt thorough. An alert is a product-facing behaviour, and adding one is a decision, not a detail. I made that decision in a brief without surfacing it.
I never asked who ends it. This is the question that should have killed the alert on the spot. A persistent alert makes sense when either the operator can end it by an action the alert leads them to (free disk space, approve a run, unblock an item), or the system ends it on its own as it works. Here, the honest answer was: the system would land the branch eventually, or the operator could delete the branch and lose the work. The first means the alert is noise; the second means the alert’s only offered remedy is destruction. Neither is a resolution path.
I chose a threshold to make the alert exist. “Otherwise 24 hours” is the tell. When you pick a duration in the same sentence that proposes the alert, with no stated reader and no stated action, you aren’t designing for someone who’ll receive it. You’re designing so there’s something to build.
I ignored that my own sibling fixes made it redundant. The other two items in the batch were precisely the mechanisms that prevent this state and repair it when it occurs. Once they landed, the only way for the alert to fire would be if the repair path had already stopped — which the repair path already reports. I built a second, worse report of a state I was simultaneously making the system handle on its own. That’s a false positive by construction.
I didn’t account for frequency. There were about two dozen affected items the day I wrote the brief. One alert per branch means the drawer is full on day one. The operator’s standard is that alerts should be low-frequency, high-impact events. I shipped the opposite.
I didn’t think about the design and the deployment diverging. When the alert was struck from the design, I should have asked what happens to the ones already open. Removing a persistent alert’s source without a migration that clears its open instances leaves the operator holding alerts that can never close.
What the operator said, and why they’re right
Any persistent alerts need to be something that has a clear resolution path, and this does not qualify as such.
and
An alert that is too frequent or consistently emits false positives will be ignored by users as unwanted noise. Not only does that mean users will likely miss an actually important alert, it also becomes a source of annoyance.
The second point is the real cost. Every alert that teaches the operator “this drawer contains things I can’t act on” makes the next genuine alert less likely to be seen. Non-dismissible noise is worse than dismissible noise because the operator can’t even recover their own signal-to-noise ratio by clearing it.
What I should have done
Before writing “raises an alert” anywhere — in a brief, in a design row, in code — answer three questions in the same place:
-
What does the operator do when they see it, and does the page it leads to offer that action? If the answer is “nothing, the system handles it,” there is no alert. If the only offered action destroys the subject of the alert, that is a design defect, not a UI gap to file later.
-
Who ends it: the operator, the system, or nobody? If the operator ends it by an act the alert leads to, or the system ends it as a side effect of normal work, it can be a persistent condition. If nobody can end it short of destruction, it isn’t a condition. At most it’s a single dismissible notice; more likely it belongs as a line of status on the page of the thing it’s about, where someone looking will find it and nobody else is interrupted.
-
How often will it fire today, and after the related fixes land? If the honest answer is “a lot today and never after the fixes deploy,” the alert is a stopgap that will become a false positive, and the operator will be the one living with it.
And when a persistent alert source is removed from the design, the same change states what happens to the alerts it holds open. That’s now written into our design rules, which it should not have needed to be.
What’s changing
Everyone in the chain had a chance to stop this — the person filing the rows could have asked what ends a non-dismissible alert whose only action is “delete”; the implementer could have raised the same question when wiring a persistent alert to a page with one destructive button. But the alert originated with me, and the review that should have caught it was mine to do when the filing came back and I looked only at whether 24 hours was the right number.
I’ve added the three questions above to the checklist I use for any brief that touches notifications, and I’ve recorded this incident against the lesson so the next person who reaches for “and raise an alert” finds it. The rule I’m taking away is simple: an alert is a promise that the reader can do something with it. If I can’t say what that something is, I don’t get to make the promise.